UCS: After firmware upgrade B230 M1 blade is failing discovery at 4%

15 Dec

After upgrading B230 M1 blade it gets stuck in discovery at 4% and is showing following errors:

no connection to MC endpoint
1

Error retrieving Server Params-MC Error(-6): Connection is closing

2

No DIMMs present

3

The errors can be rotating but it is stuck at 4%.

1. Check Firmware versions and see if all are as expected.
3_5

2. Reset CIMC and after this is done Reacknowledge the server.
3. Check the firmware versions of the blade again. The Running Board Controller version is set to 00000000
4

4. Activate the Board Controller with correct version and wait until activation is finished.
5

5. Reacknowledge the server

Tags: , , ,