06 Feb

This is a quick post for simple error that you might see in Cisco UCSM.
t1
Affected object: sys/chassis-2/fan-module-1-2
Description: Fan module 1-2 in chassis 2 temperature: upper-critical
Cause: thermal-problem
Code: F0382

This may indicate that there is hardware problem with the fan and it needs to be replaced but quite often it indicates logical problem. There are a few bugs depending on the version that UCS is running that might cause this behaviour.
As we can see from the error the problem is with the fan in chassis 2.
If you click on the blue text it will open a new window and you’ll be able to see which fan it is.
t2

The first thing you can try is to reseat the fan and see if the error goes away. If it does not then it most likely hardware issue.
In this case the error has cleared.
This error might reappear in couple day/weeks or months or it could happen on the other fan. There is a known I2C bug in UCS. To clear i2c bus it is advised to reseat all fans, PSUs and IOmodules(one at a time).
The bug was fixed in late 1.4(3*) version but was reintroduced again in 2.0 version. It should be fixed in latest version.
I UCS system affected by this bug than you still need to reseat components as the upgrade alone will not clear the I2C bus.
IMO it would be best to reseat them before upgrading as at least you’ll be upgrading a healthy system.

UCS: Update firmware on Cisco UCS C200 server using Host Update Utility


06 Feb

Here is a simple procedure how to update firmware on UCS C200 M2 server. The procedure should be no different on the other models of C series servers as they use Host Update Utility(HUU).
1. First you need to download the firmware for the upgrade. In this instance the server will be upgraded to 1.4(3p)5

  • Go to Cisco.com, select Support and All Dowloads 
  • Choose Servers- Unified Computing and Cisco UCS C-Series Rack-Mount Standalone Server Software. Select your server model(in this case it is C200 M2)
  • From select Software type choose Unified Computing System (UCS) Server Firmware
  • Find the required version and download it(you’ll need to login). It will be iso file:

    1

2. Mount HUU iso in CIMC (more…)